Loading data. Please wait

IEC 60269-2 Ed. 5.1 b:2016

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K CONSOLIDATED EDITION

Pages: 812
Publication date: 2016-08-05
Price: 586 vnd

Add to cart
IEC 60269-2:2013+AMD1:2016 provides supplementary requirements for fuses for use by authorized persons and are generally designed to be used in installations where the fuse-links are accessible to, and may be replaced by, authorized persons only. Fuses for use by authorized persons according to the following fuse systems also comply with the requirements of the corresponding subclauses of IEC 60269-1, unless otherwise defined in this standard. This standard is divided into fuse systems, each dealing with a specific example of standardized fuses for use by authorized persons: - Fuse system A: Fuses with fuse-links with blade contacts (NH fuse system), - Fuse system B: Fuses with striker fuse-links with blade contacts (NH fuse system), - Fuse system C: Fuse-rails (NH fuse system), - Fuse system D: Fuse-bases for busbar mounting (NH fuse system), - Fuse system E: Fuses with fuse-links for bolted connections (BS bolted fuse system), - Fuse system F: Fuses with fuse-links having cylindrical contact caps (NF cylindrical fuse system), - Fuse system G: Fuses with fuse-links with offset blade contacts (BS clip-in fuse system), - Fuse system H: Fuses with fuse-links having "gD" and "gN" characteristic (class J and class time delay and non time delay fuse types), - Fuse system I: gU fuse-links with wedge tightening contacts, - Fuse system J: Fuses with fuse-links having "gD class CC" and "gN class CC" characteristics (class CC time delay and non-time delay fuse types), - Fuse system K: gK fuse-links with blade for bolted connections - High fuse-link ratings from 1 250 A up to 4 800 A (master fuse-links). This fifth edition of IEC 60269-2 cancels and replaces the fourth edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1. fuse systems A and B: modified values for the power dissipation of NH aM fuse-links; 2. fuse systems A and B: introduction of dimension r for NH fuse-links; 3. addition of new fuse system K: gK fuse-links with contacts for bolted connections. Key Words: fuse systems A to K, requirements for fuses This publication is to be read in conjunction with IEC 60269-1:2006. This consolidated version consists of the fifth edition (2013)) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
Document identifier
IEC 60269-2 Ed. 5.1 b:2016
Title
Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K CONSOLIDATED EDITION
IEC Category
SC 32B: Low-voltage fuses
Publication date
2016-08-05
Status
Effective
International Relationship
Cross references
Latest version
IEC 60269-2 Ed. 5.1 b:2016
Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K CONSOLIDATED EDITION
Document identifier IEC 60269-2 Ed. 5.1 b:2016
Publication date 2016-08-05
Classification 29.120.50. Fuses and other overcurrent protection devices
Status Effective
*
History of version
IEC 60269-2 Ed. 5.1 b:2016 * IEC 60269-2 Ed. 5.0 b:2013 * IEC 60269-2 Ed. 4.0 b:2010 * IEC 60269-2 Ed. 3.0 b:2006 * IEC 60269-2 Ed. 2.0 b:1986
Keywords
Pages
812
Price 586 vnd