The ASME A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts presents certain guides for the design, construction, installation, operation, inspection, testing, maintenance, and repair of inclined stairway chairlifts, and inclined and vertical platform lifts. It covers devices intended for transportation of a mobility-impaired person only—typically within household applications. The ultimate goal of this Standard is to help protect public safety, while reflecting best-practices of industry.
Key changes to this Edition include:
Engineering Tests
Free fall overspeed testing
Independent lab certification
Testing at max (45 degrees) and min angle of product capability
Full load and no load
Re-Locatable Lifts
New definition for class of platform lift
Level surface detection — more than 5% or 1:20 slope lift cannot run
Manufacturer to test for stability at top of travel when on a 5% slope
Signage regarding top landing alignment
Electrical connection means meeting NFPA 70 (can be on lift)
Retractable or removable wheels to be monitored and lift only operable when retracted or removed
Maintenance
New definitions for Authorized personnel and Lift personnel
Updates to current code sections where new definitions apply
New section 11 for Maintenance
Platform-mounted sidewalls
Allowance for the installation of only one platform wall
Any non access side of the platform with no wall shall be equipped with an edge protection device.
A grab rail shall extend not less than 10mm (0.375 in.) nor more than 75 mm (.75in.)
If equipped with protection on the top edge of the enclosure wall side wall running clearance to enclosure wall may be not less than 10mm (0.375 in.) nor more than 75 mm (.75in.)
Emergency Signals
Audible signaling device to be located outside platform and outside the runway
Audible signaling device sound rating not less than 70dBA and not more then 80dBA 120" from lift
Lifts installed in areas not normally occupied when lift is in use shall be provided with a means of two-way conversation to building or emergency personnel
Audio Alarms
Move from inside to outside the platform and runway
Install alarm adjacent to the lift
Reduce dBA level from 80 down to 70 at 120"
Safeties and Governors
Removal of the use of self-locking drive on residential inclines and stair chair lifts
Residential inclines and stair chair lifts now require speed governor
Alternate to speed governor can be substituted by systems designed so no overspeed can occur in the event of a single failure of a drive component
Document identifier
ASME A18.1-2017
Title
Safety Standard for Platform Lifts and Stairway Chairlifts
ASME Category
Elevators and Escalators
Publication date
2017-10-05
International Relationship
History of version
ASME A18.1-2017 * ASME A18.1-2014 * ASME A18.1-2011 * ASME A18.1-2008 * ASME A18.1-2005 * ASME A18.1-2003 * ASME A18.1-1999
Price |