Loading data. Please wait

ISO 10295-2:2009

Fire tests for building elements and components - Fire testing of service installations - Part 2: Linear joint (gap) seals

Pages:
Publication date: 2009-02-01
Price: 138 vnd

Add to cart
ISO 10295-2:2009 specifies the heating conditions, methods of test and criteria for the evaluation of the ability of a linear joint seal to maintain the fire integrity and thermal insulation of a fire-separating element at the joint being sealed. The purpose of the tests is to assess the integrity and insulation performance of the linear joint seals, including the effects of induced movement in those cases where the joint is designed to accommodate movement and has a width greater than 20 mm.It is not the intention of this part of ISO 10295-2:2009 to provide quantitative information on the rate of leakage of smoke and/or gases, or on the transmission or generation of fumes, although such phenomena can be recorded in describing the general behaviour of specimens during the test. It is not the intention of this part of ISO 10295-2:2009 to evaluate joint seals where special test procedures already exist, e.g. doors, partitions, penetrations, pipes, ducts and cables.
Document identifier
ISO 10295-2:2009
Title
Fire tests for building elements and components - Fire testing of service installations - Part 2: Linear joint (gap) seals
ISO Category
TC 92/SC 2: Fire containment
Publication date
2009-02-01
Status
Effective
International Relationship
BS ISO 10295-2:2009 * BS ISO 10295-2:2009
Cross references
Latest version
History of version
Keywords
Pages
Price 138 vnd